Three Phase 1250kVA Open Frame Avespeed Diesel Generator Set/Generator Set/Generator Set

Three phase 1000kw open style diesel generator set Standard Features:1.All generator set comply with international design and quality standards, such as ISO8528(GB/T2820-97), ISO3046,BS.EN60034, BS5000, IEC34-1, GB755, VDE0530, CS

Featured Products

Three phase 1000kw open style diesel generator set
 
Standard Features:
1.All generator set comply with international design and quality standards, such as ISO8528(GB/T2820-97), ISO3046,
BS.EN60034, BS5000, IEC34-1, GB755, VDE0530, CSA22-2, AS1359, and so on.
2.Engine and alternator coupled with the compact base of structure steel, equipped with exhaust silencer and radiator.
3.AVESPEED designed controller IS900 and multiple circuit breaker as a standard configuration for single unit.
4.One year limited warranty covers all systems and components.
 
>>Prime power(Unlimited Time Running)
This rating is applicable for supplying electrical power in lieu of commercially purchased power. 
Variable load should not exceed a 70% average of the prime power rating during any operating period of 250 hours, 
The total operating time at 100% prime power shall not exceed 500 hours per year and this model can supply 10% over-load power for 1 hour in 12 hours.
>>Standby power
There rating should be applied where reliable utility power is available. 
A standby rated engine should be sized for a maximum of an 80% average load factor and 200 hours of operation per year. 
No overload capability is available for this rating.
 
NOTE 1:
All data is based on:
1. Engine operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust silencer; 
not included are battery charging alternator, fan, and optional driven components.
2. Engine operating with fuel corresponding to grade No. 2-D per ASTM D975.
3. ISO 3046, Part 1, Standard Reference Conditions of:
  Barometric Pressure: 100 kPa (29.53 in Hg)
  Air Temperature : 25 degree centigrade; 
Altitude:110 m (361 ft); Relative Humidity:30%;
  Air Intake Restriction: 254 mm H2O (10 in H2 O);Exhaust Restriction : 51 mm Hg (2 in Hg).
4. Backed by worldwide service network.
N/A : Not Available;
TBD: To Be Determined;

NOTE 2:
1. Alternators meet the requirement of BS EN 60034 and the relevant section of other international standards such as BS5000, 
VDE 0530, NEMA MG1-32, IEC34, CSAC22.2-100, As1359, 
and other standards and certifications can be considered on request.
2. Brushless alternator with brushless pilot exciter for excellent load response.
3. Backed by worldwide service network.

 
Specifications of Genset
Model SpecificationKTA50-G3 
BASIC TECHNICAL DATA 
Engine type4-cycle,T=turbocharged, -/A=- /water-air after-cooled 
Cylinder arrangement  16cylinders,Vee 60° 
Bore and stroke(mm)159×159 
Compression ratio13.9:1 
Displacement(L)50.3 
Estimated total weight (dry)(kg)  4858 
Engine rated speed(rpm)1500 
Prime power(kW).gross1097 
Standby power(kW).gross  1227 
EXHAUST SYSTEM 
Air intake flow(L/sec).rate       1546 
Exhaust flow ( L/sec ).rate4231 
Exhaust temperature.rate 583 
Max. back pressure(kpa)10 
Diameter of exhaust pipe (mm)TBD 
COOLING SYSTEM 
Coolant capacity(only engine)(L)   161 
FUEL CONSUMPTION 
Standby power(L/h)282 
100% prime power(L/h)254 
75% prime power(L/h)195 
50% prime power(L/h)  138 
LUBRICATION SYSTEM 
Oil pan capacity(L)177 
ELECTRIC SYSTEM 
Governor typeElectronic 
Starter motor24V 
Battery charging system35A 
Three Phase 1250kVA Open-Frame Avespeed Diesel Generator Set/Generator Set/Genset
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours