80kw with Perkins diesel generator set (GF1- 80KW )

80kw with perkins engine diesel generator set (GF1-80KW)1. We are manufactory, could give best suggestions to customers.2. Professional general engineers and technical team.3. Have spare parts for customers' exchange.4. Warranty: Running 500 hours or one year.5.100% copper good brand alternator,

Featured Products

80kw with perkins engine diesel generator set (GF1-80KW)

1. We are manufactory, could give best suggestions to customers.

2. Professional general engineers and technical team.

3. Have spare parts for customers' exchange.

4. Warranty: Running 500 hours or one year.

5.100% copper good brand alternator, every spare parts suppliers are choosed extremely stricted, to control the quality well.

6. From engine to whole genset, we test every link of every product, have test machinery and test center.

7. Many spare parts are produced by ourselves, could save cost for customers greatly.

8. We welcome every customer visiting our factory and test our products.
MODEL  GF1- 80KW
Standby Power  (50HZ )88KW / 110KVA
Prime Power  (50HZ )80KW / 100KVA 
VoltageFrequency(HZ)PhaseP.F Standby Amps Standby Ratings (KW/KVA)Prime Ratings(KW/KVA)
440/2545030.814488/11080/100
415/2405030.815388/11080/100
400/2305030.815988/11080/100
380/2205030.816788/11080/100
Standby Power Rating(ESP):The standby power rating is applicable for supplying emergency power for the 
duration of a utility power interruption.No overload,utility parallel or negotiated outage operation capability 
is available at this rating. 
Prime Power(PRP) : Prime power is available for an unlimited number of annual hours in variable load 
application,in accordance with GB/T2820-97 (eqv ISO8528);A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation. 
ENGINE DATA 
Engine Type  / :    Perkins Engine 1006TG2A.  Four stroke,Water-cooled,Direct line,Turbo type  1006TG2A 
 Rated RPM   (r/min)1500rpm
Cooling System  Forced Water-cooled 
Fuel Consumption  ( ≤ g/kw.h)≤ 214
 Compression Ratio 17.5:1
 Bore ×Stroke  ×  (mm)100×127
Displacement  (L)5.99
Governor Type Mechanical 
Steady State Frequency Regulation ±0.5%
RPM of Piston 6.35m/s
 Start Method Electric Start 
ALTERNATOR DATA 
Alternator Data 
 Power Factor  0.8 Lag 0.8
 Insulation Class H
 Lubricating System    Pressure,Split,Complex 
exhaust Air Temperature ≤ 550
Altitude ≤1000m
Connecting Type3 Phase and 4 Wires,"Y" type connecting
 Intake Type Natually-Aspirated 
 Rated Speed Regulation  %≤ ±1%
Alternator Efficiencies 90.40%
Air Cooling Flow :30.84m3/s
Phase 3
Dimension & Weight
Open TypeSoundproof Type 
Overall Size:2.3(m)×0.8(m)×1.56(m) Overall Size  :3.2(m)×1.08(m)×1.65(m)  
Weight: 1090kgWeight  : 1875kg 



Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours