100kVA diesel generator driven by Perkins engine (HY-P110)

Product Description 100KVA Perkins Silent Generator, Diesel Generator Set 1.Power by Perkins Engine2.With Stamford / Leroy Somer / Marathon Alternator3. With CHINT / ABB MCCB & Electronic Components4. Electric Start with&

Featured Products

Product Description 100KVA Perkins Silent Generator, Diesel Generator Set 

1.Power by Perkins Engine
2.With Stamford / Leroy Somer / Marathon Alternator
3. With CHINT / ABB MCCB & Electronic Components
4. Electric Start with Battery
5. Base Integrated Fuel Tank
6. ATS, Deepsea / ComAp / Smartgen Controller
7. Comply with ISO9001/CE 
8. After-sale Services

Control Systems

Standard control panel is the basic configure for normally operation and usage. The advantages of this panel are easy operation, aomprehensive function and reliable protection and so on. There are indicating gauges, lamps, transfer switches and emergency stop button, etc. The control panel wil stop the whole generator set and alarm as well when malfunction appears.

LED Automatic Control Panel is a kind of intelligent controller with LED displaying the operating mode of the controller and the running state of the generator sets. It can configure the control procedure and protection parameter of the generator set, and completely satisfied the automatic controlling requirement of the generator sets for the user or factory.

AMF Automatic Control Panel is the configuration for nobody on duty controlling generator sets. This kind of panel adopts module control system, with large LCD screen to show the menu. The module can receive output signal from ATS and realize automatic start and stop the generator set.

ATS(Fully Automatic) is the standard configure of emergent power system. It detects the voltage and frequency of main power timely. While there is something wrong, such as high voltage, low voltage, phase missing, electricity cutting off, etc., it will signal to start the generator set automatically; 
While main power resumes balanced, it controls the generator set to shut down after cooled.

Engine
*Heavy duty diesel engine
*Four stroke, water cooled
*12V and 24V stater and charge alternator
*Cooling radiator and fan
*Maintenance free battery including ract and cable
*Flexible fuel connection hoses and manual oil sump drain valve
*Exhaust silencer
Alternator
*Brushless, single bearing, flexible disc
*Insulation class: H
*Protection class: IP23
*Self-exciting and Self-regulation
Canopy
*All canopy designed with modular principles
*All metal canopy parts painted by electrostatic polyester power paint
*Soundproof design ensure that the noise level be controlled in small scope
*Convenient to lift and move
*Easy to maintenance and operate
 
Base Frame
*Base frame including position for forklift and crane
*Integral fuel tank
*Daily fuel tank continuously supply for 8-24 hours
*Fuel tank easy to maintain and clean
*Anti-vibration pads are flexed between engine and alternator.
 
Control System
*Control, monitor and protect the Generator Set including:
*High water temperature
*Low oil pressure
*Over and under speed
*Over current
*Under/Over generator voltage
*Start and stop failure
*Low and high battery voltage
*Charge fail
*Emergency stop

 



DIESEL
GENERATOR
SET
Diesel GenSet ModelHY-P110
Prime power (KW/KVA)80/100
Standby power (KW/KVA)88/110
Rated voltage(V)230/400
Rated current (A)144
Frequency(Hz)50
Rated Rotary Speed (RPM)1500
Power factor0.8
Power supply mode3 phase,4wire
Starting method24 V DC






ENGINE
Diesel Engine Perkins
Model1104C-44TAG2
Engine prime power (KW/KVA)93.6/117
Engine standby power(KW/KVA)105/131.25
Cylinder Qty.4
Fuel consumption.(L/ h)205
Bore(mm) *Stroke (mm)105*127
Compression rate18.23:1
Cooling liquid volume (L)13.6
Displacement(L)4.4
Lubricant capacity (L)8
Cooling methodWater cooled
Intake methodTurbocharged.Inter-cooled




ALTERNATOR
Alternator Features:
1. Kaijie,ENGGA,Stamford, Leroy Somer, Marathon
2. Brushless, 4 poles, rotation magnet
3. IP21-23(NEMA1) enclose is standard for all industrial alternators
4. H class insulation system
5. AVR self-regulated, voltage regulation rate: ≤±1%
6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts
7. Wide range of flange adapters and single bearing disc coupling
8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528
9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

COMPANY
100kVA Diesel Generator Powered with Perkins Engine (HY-P110)
100kVA Diesel Generator Powered with Perkins Engine (HY-P110)


RELATED PRODUCT
 You can choose other products on our website

100kVA Diesel Generator Powered with Perkins Engine (HY-P110)


PACKAGE&Delivery
Stardard size plywood
100kVA Diesel Generator Powered with Perkins Engine (HY-P110)

Product details


100kVA Diesel Generator Powered with Perkins Engine (HY-P110)
QUANLITY

100kVA Diesel Generator Powered with Perkins Engine (HY-P110)


CUSTOMER DISPLAY
100kVA Diesel Generator Powered with Perkins Engine (HY-P110)

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours